Fire-Rated Insulated Access Door with Drywall Flange

Self Latching tool-key operated slam latch and ring operated slam latch

This fire rated insulated access door can be installed on fire rated walls and ceilings.

FRI Access Door Specifications

Material – 20-gauge galvanneal steel door and 16-gauge cold rolled steel frame

Hinge – Continuous piano hinge. Hinge location: Hinges must be located on the second dimension (height)

Locking mechanism – Self-latching tool-key operated slam latch and ring operated slam latch, both included

Flange – 22-gauge galvanized steel, 1 ⅛” drywall bead flange

Frame – 2½ ” in depth, made of cold rolled steel

Rough opening – Door sizes + ¼” or + 6 mm

Insulation – 2″ thick fire rated mineral wool

Inside panel release – Mechanisms to allow panels to open from inside, standard on all doors over 12″ X 12 inches

Finish – High quality white powder coat primer

Packaging – Individually wrapped, 1 door per box

Vertical wall assemblies – Fire rated access doors, for vertical use, are subject to the following:

Certification – UL 10B (2009), NFPA 252 (2012), CAN/ULC S104 (R1985), CAN/ULC S104 (2010)

Rating Achieved – 3 hours, neutral/negative pressure

Maximum size –48″ x 48″ (1219mm x 1219mm), maximum area of 2304 in², tolerance on height and width limitation is more or less 3″ (76mm) as long as the area does not exceed 2304 in²

Temperature rise – 250°F (121°C) after 30 minutes and 450°F (232°C) after 60 minutes

 Horizontal ceiling assemblies – Fire rated access doors, for horizontal use, are subject to the following:

Certification – ASTM E119 (2012), CAN/ULC S101 (2007)

Rating Achieved – 3 hours in non-combustible construction and 1 hour in combustible construction

Maximum size – 24″X36″ (610 mm X 914 mm) (hinges and latches on the side of 36″), tolerance on dimension limitations are more or less 3″ (76 mm) as long as the area does not exceed 864 in²

Temperature rise – Within allowable per ASTM E119 and CAN/ULC S101

 

For High security PFI-HS: Optional 14 gauge cold rolled steel frame and 16 gauge galvanneal steel door

If door size exceeds 24″ X 36″, the latter is not fire-rated for ceiling installation. All dimensions are written in the following order: Width X Height

Description

Fire-Rated Insulated Access Door with Drywall Flange

This fire rated insulated access door can be installed on fire rated walls and ceilings.  The drywall bead flange is not exposed once the drywall compound is applied.

  • Installation: Walls and ceilings
  • Material: Galvanneal steel
  • Locking mechanism: Ring/tool key operated slam latch
  • Self Latching tool-key operated slam latch and ring operated slam latch
  • Hinge: Piano hinge
  • Flange: Drywall bead flange
  • Size: Other sizes available upon request

Additional information

Weight N/A
Dimensions N/A
Size

8"x8", 10"x10", 12"x12", 14"x14", 16"x16", 18"x18", 22"x22", 22"x30", 22"x36", 24"x24", 24"x36", 24"x48", 30"x30", 32"x32", 36"x36", 48"x48"